Release Notes

6.0.28 (22/10/2026)

bugfix
  • fix: on the SP259 and SP259i, a protocol trigger (a UART byte, for example) no longer misses its frame when the traffic just before it partly matched it
  • improvement: SP259 firmware 10

6.0.27 (22/10/2026)

bugfix
  • fix: on the SP259 and SP259i, a second capture no longer hangs until the device is unplugged (a regression in 6.0.26)

6.0.26 (21/10/2026)

bugfixfeaturemajor
  • feature: decoder scripts can build protocol triggers
  • feature: the pattern generator shows when a pattern is being built
  • feature: crash reports now carry a stack trace for native faults and freezes
  • fix: on the SP1000G, a stopped state clock no longer wedges the USB link
  • fix: on the SP1000G, a capture reports the depth it actually reached, not only its last 50 ms
  • fix: on the SP1000G, state captures no longer repeat samples at the end of a burst
  • fix: on the SP1000G, an external trigger now sets the other trigger engine aside
  • fix: on the SP1000G, a capture on the 10 MHz IN timebase is refused when no usable 10 MHz signal is present
  • fix: on the SP1000G, the device is reopened correctly after a firmware reboot
  • fix: on the SP259, the USB link is flushed before a capture, so an interrupted capture no longer leaves stale data behind
  • fix: the interface no longer stalls while a long pattern is being counted
  • improvement: SP1000G firmware: controller 0.16.303, core 0x19

6.0.25 (18/10/2026)

bugfixfeature
  • SP1000G timebase (internal or external), TRIG OUT polarity and TRIG IN threshold capture settings
  • SP1000G probe serial numbers, shown under the probe name
  • on the SP1000G, closing a workspace that ran the pattern generator no longer makes the next capture fail with "interface is busy" or wait 5 s
  • a portable copy can open its script library, autosave and logs folders again
  • a malformed or out-of-range protocol command is now reported instead of silently taking a default
  • SP1000G controller firmware 0.15.298

6.0.24 (16/10/2026)

bugfix
  • the "server unreachable" notice no longer flashes at start-up while the server is still launching, and no longer restarts a server that is still booting

6.0.23 (15/10/2026)

bugfixfeaturemajor
  • SP259 and SP259i trigger loopback test for production benches — with TRIG OUT shorted to TRIG IN, a capture started with ext_trig_test fires its external trigger through the short (refused on other devices)
  • a Memory View per decoder, showing what a script reads out of the target, with selection, copy as raw bytes and a choice of byte order
  • pattern generator scripts can pause and resume, a decoder can resume or stop the generator, and the generator's console reaches the log as it writes
  • a script names the channels it drives, and asks before using them
  • the marker snap is a setting, with a key that reverses it while held
  • SP209 rev A firmware is checked and updated like the other revisions
  • SP259 firmware version 9 and SE254 firmware version 4
  • views open themselves when new data arrives, and a closed one is flagged instead
  • the SQ mode names every wiring it cannot run, offers to fix it, or offers the other mode
  • a workspace and its detached views are named after their file
  • the Log View scrolls smoothly through long logs, gives each line of a multi-line entry its own row, and stamps lines to the millisecond
  • a P992 channel shows its own threshold in its header
  • the dialogs share one behaviour: Escape cancels, a click beside them closes nothing, and the draggable ones drag
  • a stop pressed while a capture is still preparing cancels it, and a start sent while another is on its way is answered
  • a capture start waits for the device to be read instead of failing
  • a trigger step with an unknown cell is refused instead of being read as "don't care"
  • an SP259 capture cut short no longer leaves unread data behind for the next one
  • SP1000G resumed acquisitions placed their sync edge where the levels start
  • a generation stopped mid-start no longer freezes the generator, huge repeats play in full, and closing a workspace stops its generation
  • a generator configuration that became invalid refuses the capture instead of running it
  • generator marks are kept in a saved workspace
  • a load, save or export is answered only after its events, and only to the client that asked
  • a crashed worker thread is reported instead of hanging the workspace

6.0.22 (05/10/2026)

bugfix
  • on macOS, the server was stopped by the system as soon as an SP209 was opened, so no capture could start
  • on older macOS versions, parts of the waveform overlay (minimap, markers, gauges) were not drawn

6.0.21 (05/10/2026)

bugfix
  • on macOS, no SP209, SP259, SP1000G or ScanaQuad was detected, because macOS refused to load the USB libraries shipped with the application

6.0.20 (04/10/2026)

bugfix
  • on macOS and Linux, an SP209, SP259, SP1000G or ScanaQuad could go undetected because the server did not find the USB libraries installed with the application
  • when a USB library cannot be loaded, the log now says why and where it was looked for

6.0.19 (03/10/2026)

bugfixfeature
  • a script that needs to open a file outside its own folder now asks for permission, naming the script and the path, instead of failing silently
  • on macOS the SP209 and SP209i were never detected, and only the demo device was offered
  • on Ubuntu 22.04, Debian 12 and RHEL 9, SP209 and ScanaQuad devices were not listed, because the bundled FTDI library needed a newer system than these provide
  • on Linux, an SP209i that presents itself as a plain FTDI chip could be listed but not opened
  • on Windows, the application could not start its server on a machine without the Microsoft Visual C++ runtime
  • on the SE254, after a capture was stopped while waiting for its trigger, later captures never triggered

6.0.18 (28/09/2026)

bugfixfeaturemajor
  • the ScanaQuad family (SQ25, SQ50, SQ100, SQ200), with its pattern generator, capture and I/O configuration
  • an inputs / outputs window with a wiring schematic of each channel's termination
  • in Generation or Mixed mode every output channel gets its own row holding what the next generation replays, filled from the capture, at a constant level, drawn by hand or by a script
  • signal builder scripts (on_build_signals) run with their configuration form, as in ScanaStudio 3
  • measurements on generation rows, and a mixed run shows the replayed region in a loop
  • a new trigger step starts from the levels the previous step leaves instead of don't care
  • the miniview's grips resize the visible zone
  • the SP259 reports its clock and each memory bank in the device information
  • a multistep trigger combining a held level, an edge and a time window never fired
  • an external trigger on a device with no TRIG IN fired at once; it is now refused
  • the cursor readout inverted duty cycle and pulse level on every channel
  • a marker can no longer be placed or moved before the first sample
  • the memory depth list offered one step past the device's memory

6.0.17 (23/09/2026)

bugfixfeaturemajor
  • a portable edition for Windows — a .zip that runs where it is unpacked, keeps its logs, autosaves and script library in a data folder beside it, and updates itself in place
  • rows can be selected (click, Ctrl, Shift), dragged as a group, and pinned to the top of the plot while the rest scrolls behind them
  • a channel follows the pointer while it is dragged, and a drag held at the edge scrolls the view
  • a probe port's configuration can be copied and pasted onto another port, in the same workspace or another one
  • a trigger engine's configuration can be copied and pasted onto the other engine or another workspace, adapted to the target device
  • every workspace ScanaStudio 5 opens can now be imported, including files from ScanaStudio 2 to 4.1, with hidden channels and row order kept
  • the script library folder can be changed in Settings
  • the third-party licence notices ship with the application and open from the About window
  • the About window shows the script API and SDK versions, and where the server runs
  • the P992 window keeps a threshold per channel, saved with the workspace
  • SP1000G controller firmware 0.12.252
  • a capture that is refused offers "Show the trigger" only when the trigger is the reason
  • a click beside a dialog no longer closes it and throws away what was typed
  • Cancel in Settings undoes every change, and OK is the only thing that applies one
  • a server port taken by another program no longer makes the application restart its server again and again; a free port is offered instead
  • on Windows, a second server can no longer start on a port that is already in use
  • buttons that would open a folder on a remote server's machine are disabled instead of opening the wrong local folder
  • decoder items drawn under a curve placed above a channel land on the right row
  • layered decoders using sync_decode produce their items again
  • a pattern generator's settings form reads the sample rate correctly
  • a capture imported from a ScanaStudio 5 demo device opens on the matching demo device

6.0.16 (12/09/2026)

bugfix
  • a measurement no longer stays on "Calculating" after its result is in

5.1.42 (29/06/2026)

bugfixfeature
  • Improved start and stop of all devices
  • Improved general stability and performance
  • Fixed auto-suggestion for decoder when adding pattern generator

5.1.41 (02/04/2026)

bugfix
  • Fix critical bug related to SP1000g firmware

5.1.40 (01/04/2026)

feature
  • Enhance support for newer SP1000g probes

5.1.39 (03/02/2026)

bugfix
  • Fixed visual bug at the start of acquisition
  • Improved signal navigation speed
  • Enhanced SP1000G internal DDR3 memory throughput

5.1.38 (30/10/2025)

feature
  • Enhanced support for SP1036

5.1.37 (20/10/2025)

bugfix
  • Fixed bug related to pattern loading

5.1.36 (17/10/2025)

bugfix
  • Fixed bug related to pre-trig bufferring
  • Fixed state-mode for devices sp259x

5.1.35 (02/10/2025)

feature
  • Devices SP1000g firmware update

5.1.34 (29/09/2025)

bugfixfeature
  • Improved and harmonized GUI for sampling parameters
  • Enhanced SP1000g communication and abort handling
  • Fixed timeblock issue: trigger markers can no longer be used within timeblocks

5.1.33 (08/09/2025)

bugfixfeature
  • Fixed the Center on trigger option in normal mode
  • Made the text size of time blocks configurable in settings
  • Added a splash screen on startup
  • Fixed an issue with saving the proxy port number
  • Improved how channels are hidden individually
  • Enhanced overall support and functionality for SP259x devices

5.1.32 (25/07/2025)

bugfix
  • Fixed a bug related to SP1000G edge trigger polarity
  • Improved trigger marker precision
  • Improved recovery from USB3 failure
  • Fixed a bug that caused a crash when adding a timeblock while decoders were active

5.1.31 (23/07/2025)

bugfixfeature
  • Fixed a bug that caused a crash when moving a marker while decoders were active
  • Fixed a performance issue: ScanaStudio slowed down when rendering special characters with decoders
  • Added a new feature: pre-trigger countdown